Skip to main content

Table 3 Sensitivity and specificity of proteomics and rRT-PCR analyses done in saliva samples collected from COVID-19 positive and healthy individuals

From: Identification of SARS-CoV-2 biomarkers in saliva by transcriptomic and proteomics analysis

  

COVID-19 status

  

COVID-19 status

  

Positive

Healthy

  

Positive

Healthy

Proteomics analysis

Positive

n = 42

n = 0

rRT-PCR analysis

Positive

n = 24

n = 0

Negative

n = 0

n = 16

Negative

n = 18

n = 16

Total

n = 42

n = 16

Total

n = 42

n = 16

Sensitivity and specificity

Sensitivity

1.0 (100%)

Specificity

1.0 (100%)

Sensitivity and Specificity

Sensitivity

0.57 (57.1%)

Specificity

1.0 (100%)